H3C S5000V5-EI series is the latest development of Gigabit speed managed Ethernet cambiar that is especially for SMB (Small Business) market. Besides high-performance access, it also offers abundant security access policy control and enhanced network manageability and maintenance. This makes it ideal for network construction on industries such as government, small to midsize enterprise, school and hotel.
Hoja de datos de la serie de conmutadores gestionados Gigabit H3C S5000V5-EI
H3C S5000V5-EI series Ethernet switch includes the following models:
S5008PV5-EI-S: 8*10/100/1000BASE-T Ports and 2*1000BASE-X SFP Ports
S5016PV5-EI-S: 16*10/100/1000Puertos BASE-T y 4 puertos SFP 1000BASE-X
S5024PV5-EI-S: 24*10/100/1000Puertos BASE-T y 2 puertos 1000BASE-X
S5024PV5-NO: 24*10/100/1000Puertos BASE-T y puertos 4*1000BASE-X
S5048PV5-NO: 48*10/100/1000Puertos BASE-T y puertos 4*1000BASE-X
S5008PV5-NO-HPWR: 8*10/100/1000Puertos BASE-T PoE+ y 2*puertos SFP 1000BASE-X
S5016PV5-EI-PWR-S: 16*10/100/1000Puertos BASE-T PoE+ y 2*puertos SFP 1000BASE-X
S5024PV5-EI-PWR-S: 16*10/100/1000Puertos BASE-T PoE+, 8*10/100/1000Puertos BASE-T y 2 puertos 1000BASE-X
S5024PV5-NO-HPWR: 24*10/100/1000Puertos BASE-T PoE+ (CA 370W) y 4 puertos SFP 1000BASE-X
Características | S5008PV5-EI-S | S5016PV5-EI-S | S5024PV5-EI-S | S5024PV5-NO | S5048PV5-NO |
Capacidad de conmutación | 20Gbps | 40Gbps | 52Gbps | 56Gbps | 104Gbps |
Tasa de reenvío de paquetes | 15diputados | 30diputados | 39diputados | 42diputados | 78diputados |
Puerto de gestión | 1 puerto de consola | ||||
10/100/1000 Puerto Base-T | 8 | 16 | 24 | 24 | 48 |
Puerto SFP | 2 | 4 | 2 | 4 | 4 |
Características del puerto de cobre | semidúplex, duplex completo, negociación automática | ||||
MDI/MDI-X | |||||
Funciones Ethernet | LLDP | ||||
Configuración de MAC estática | |||||
Límite de aprendizaje de direcciones MAC | |||||
Espejo de babor y espejo de flujo | |||||
Agregación de enlaces (hasta 8 puertos por grupo) | |||||
Aislamiento de puertos | |||||
STP/RSTP/MSTP | |||||
IEEE 802.3ad (agregación de enlaces dinámicos), agregación de puertos estáticos | |||||
VLAN | 802.1q ( hasta 4K VLAN) | ||||
VLAN basada en protocolo | |||||
VLAN basada en subred IP | |||||
VLAN basada en MAC | |||||
VLAN INVITADA | |||||
enrutamiento IP | Enrutamiento estatico | ||||
DHCP | Retransmisión DHCP | ||||
Cliente DHCP | |||||
Espionaje DHCP | |||||
Opción de espionaje DHCP82 | |||||
Transmisión | Espionaje IGMP V1/V2/V3 | ||||
QoS | QoS de servicio diferencial | ||||
WRR/HQ-WRR | |||||
802.1pag, Mapeo de prioridad DSCP | |||||
Límite de velocidad del puerto direccional | |||||
LCA | ACL en capa 2, capa 3 y capa 4 | ||||
ACL en IPv4, IPv6 | |||||
ACL de VLAN | |||||
IPv6 | Enrutamiento estático IPv6, doble pila | ||||
Cliente DHCPv6, Espionaje DHCPv6 | |||||
DAKOTA DEL NORTE, PMTU | |||||
Ping de IPv6, Telnet IPv6, IPv6 SSHv2, Resolución de nombres de dominio IPv6 | |||||
Fiabilidad | parche caliente, actualización de parche en servicio | ||||
Seguridad | Gestión jerárquica de usuarios y protección con contraseña. | ||||
SSHv2 | |||||
SSL | |||||
Mecanismo de contraseña y registro FTP basado en dirección IP específica | |||||
Prevenir ataques de ARP, paquete de multidifusión desconocido, paquete de difusión, paquete de unidifusión desconocido, TTL=1 paquete y paquete de protocolo | |||||
Prevenir el ataque Dos | |||||
Enlace IP+MAC+PUERTO+VLAN | |||||
IEEE 802.1x | |||||
Autenticación de validez de dirección de origen SAVI | |||||
Radio, HWTACACS | |||||
SNMPv3 | |||||
Supresión de transmisión | |||||
Prevenir ataques a la CPU | |||||
Gestión del sistema | Consola/Módem AUX/Telnet/SSH2.0/CLI | ||||
Carga y actualización a través de FTP/TFTP/Xmodem/SFTP | |||||
SNMP V1/V2c/V3 | |||||
NTP | |||||
Registro del sistema | |||||
Gestión de clústeres | |||||
RFC 1213 MIB-2 significa Base de información de gestión | |||||
Temperatura ambiente | Temperatura de funcionamiento:-5℃ ~ 45 ℃ | ||||
Temperatura de almacenamiento:-40℃ ~ 70 ℃ | |||||
Humedad ambiental | Humedad de funcionamiento:5%~95% , sin condensación | ||||
Humedad de almacenamiento:5%~95% , sin condensación | |||||
Protección del medio ambiente | RoH de China, AEE | ||||
El consumo de energía | MÍNIMO: 6W.
MÁXIMO: 11W. |
MÍNIMO: 7W.
MÁXIMO: 16W. |
MÍNIMO: 11W.
MÁXIMO: 20W. |
MÍNIMO: 9W.
MÁXIMO: 23W. |
MÍNIMO: 18W.
MÁXIMO: 41W. |
Ventilador NO | Sin ventilador | Sin ventilador | Sin ventilador | Sin ventilador | 1 |
PoE+ | – | – | – | – | – |
MTBF(Año) | 140.82 | 136.24 | 150.86 | 150.86 | 115.68 |
MTTR(Hora) | 1 | 1 | 1 | 1 | 1 |
Peso | ≤1,5 kg | ≤2kg | ≤2,5 kg | ≤2,5 kg | ≤3,5 kg |
Rango de voltaje de entrada | C.A.: 100V~240VCA,50/60Hz; | ||||
Dimensiones (Ancho × Fondo × Alto) | 266x160x43,6mm | 330x230x43,6mm | 294x179x43,6mm | 440×160×43,6 mm | 440×230×43,6 mm |
Especificaciones (Continuado)
Características | S5008PV5-NO-HPWR | S5016PV5-EI-PWR-S | S5024PV5-EI-PWR-S | S5024PV5-NO-HPWR | S5048PV5-SIN ENERGÍA |
Capacidad de conmutación | 20Gbps | 36Gbps | 52Gbps | 56Gbps | 104Gbps |
Tasa de reenvío de paquetes | 15diputados | 27diputados | 39diputados | 42diputados | 78diputados |
Puerto de gestión | 1 puerto de consola | ||||
10/100/1000 Puerto Base-T | 8 | 16 | 24 | 24 | 48 |
Puerto SFP | 2 | 2 | 2 | 4 | 4 |
Características del puerto de cobre | semidúplex, duplex completo, negociación automática | ||||
MDI/MDI-X | |||||
Funciones Ethernet | LLDP | ||||
Configuración de MAC estática | |||||
Límite de aprendizaje de direcciones MAC (hasta 8K) | |||||
Espejo de babor y espejo de flujo | |||||
Agregación de enlaces (hasta 8 puertos por grupo) | |||||
Aislamiento de puertos | |||||
STP/RSTP/MSTP | |||||
IEEE 802.3ad (agregación de enlaces dinámicos), agregación de puertos estáticos | |||||
VLAN | 802.1q (hasta 4K VLAN) | ||||
VLAN basada en protocolo | |||||
VLAN basada en subred IP | |||||
VLAN basada en MAC | |||||
VLAN INVITADA | |||||
enrutamiento IP | Enrutamiento estatico | ||||
DHCP | Retransmisión DHCP | ||||
Cliente DHCP | |||||
Espionaje DHCP | |||||
Opción de espionaje DHCP82 | |||||
Transmisión | Espionaje IGMP V1/V2/V3 | ||||
QoS | QoS de servicio diferencial | ||||
WRR/HQ-WRR | |||||
802.1pag, Mapeo de prioridad DSCP | |||||
Límite de velocidad del puerto direccional | |||||
LCA | ACL en capa 2, capa 3 y capa 4 | ||||
ACL en IPv4, IPv6 | |||||
ACL de VLAN | |||||
IPv6 | Enrutamiento estático IPv6, doble pila | ||||
Cliente DHCPv6, Espionaje DHCPv6 | |||||
DAKOTA DEL NORTE, PMTU | |||||
Ping de IPv6, Telnet IPv6, IPv6 SSHv2, Resolución de nombres de dominio IPv6 | |||||
Fiabilidad | parche caliente, actualización de parche en servicio | ||||
Seguridad | Gestión jerárquica de usuarios y protección con contraseña. | ||||
SSHv2 | |||||
SSL | |||||
Mecanismo de contraseña y registro FTP basado en dirección IP específica | |||||
Prevenir ataques de ARP, paquete de multidifusión desconocido, paquete de difusión, paquete de unidifusión desconocido, TTL=1 paquete y paquete de protocolo | |||||
Prevenir el ataque Dos | |||||
Enlace IP+MAC+PUERTO+VLAN | |||||
IEEE 802.1x | |||||
Autenticación de validez de dirección de origen SAVI | |||||
Radio, HWTACACS | |||||
SNMPv3 | |||||
Supresión de transmisión | |||||
Prevenir ataques a la CPU | |||||
Gestión del sistema | Consola/Módem AUX/Telnet/SSH2.0/CLI | ||||
Carga y actualización a través de FTP/TFTP/Xmodem/SFTP | |||||
SNMP V1/V2c/V3 | |||||
NTP | |||||
Registro del sistema | |||||
Gestión de clústeres | |||||
Temperatura ambiente | Temperatura de funcionamiento:-5℃ ~ 45 ℃ | ||||
Temperatura de almacenamiento:-40℃ ~ 70 ℃ | |||||
Humedad ambiental | Humedad de funcionamiento:5%~95%, sin condensación | ||||
Humedad de almacenamiento:5%~95%, sin condensación | |||||
Protección del medio ambiente | RoHS, AEE | ||||
El consumo de energía | MÍNIMO: 14W.
MÁXIMO: 156W. |
MÍNIMO: 10W.
MÁXIMO: 152W. |
MÍNIMO: 13W.
MÁXIMO: 158W. |
MÍNIMO: 19W.
MÁXIMO: 448W. |
MÍNIMO: 36W.
MÁXIMO: 467W. |
Ventilador NO | Sin ventilador | Sin ventilador | Sin ventilador | 1 | 1 |
PoE+ | 125W. | 125W. | 125W. | 370w | 370W. |
MTBF(Año) | 117.08 | 86.01 | 87.06 | 52.81 | 50.19 |
MTTR(Hora) | 1 | 1 | 1 | 1 | 1 |
Peso | ≤3kg | ≤2,5 kg | ≤2,5 kg | ≤6kg | ≤6kg |
Rango de voltaje de entrada | C.A.: 100V~240VCA,50/60Hz; | ||||
Dimensiones (Ancho × Fondo × Alto) | 330×230 ×43,6 mm | 330x230x43,6mm | 330x230x43,6mm | 440×260×43,6 mm | 440×400×43,6 mm |